Three Roller Gate Common Faults and Solutions

The triple roller gate should be the most used and most common gate in the industry of intelligent channel gates. The passage time is relatively short, the number of people is large, and it is favored by the majority of customers. The following research and development to give you a brief introduction to the common faults and solutions of the three roller gate.

Three roller gate common faults and solutions:

1. The three roller gates cannot be reset in time after they are opened:

Check whether there is a 12V voltage output on the motherboard H2. There is no possibility of a problem with the motherboard. The metal switch is used to block the reset switch head. The main board is red, and the red light at the end of the reset switch indicates that there is no problem. Which one is not on and which is a problem.

Three roller gate positioning arm can not be reset:

After the credit card is opened, it cannot be reset in time. Check whether the voltage of the solenoid valve is 24V. Check whether the spring of the reset coil spring is loose or not. After the swing arm is turned left and right freely, it cannot be put on the pole.

3, the trip lever during the operation of the three roller gate:

Whether the electromagnet has electricity or whether it generates suction. Check the motherboard's terminal port H6, the voltage output is 24V, otherwise replace the motherboard. The electric chuck assembly is offset downwards, loosen the M5 screws on both sides, close the valve stem, and adjust the 0.5-1mm three-roll gate brake between the small lock on the lead plate and the electric suction plate to deal with serious problems.