Application of Flame Retardant in Cable Insulation Materials

EPDM is a terpolymer whose rheological and physical and mechanical properties (eg, flow form and crystallinity) depend on the polymer composition (ie, the comonomer contained therein). The relative number). Due to the saturated main chain, EPDM has excellent electrical insulation properties. It can be used as insulation material for medium voltage and high voltage wires and cables.

In the past, people used polyvinyl chloride as insulation material. However, EPDM shows more prominent advantages than polyvinyl chloride. In particular, it has low sensitivity to ultraviolet radiation, low toxicity and corrosion, and chemical resistance. However, EPDM is highly flammable and requires the use of a large amount of flame retardant to protect it.

In general, the amount of flame retardant should be as high as 100 parts in order to give EPDM good flame retardancy. Therefore, compared with other rubbers, EPDM is relatively expensive, but it can accept a large number of fillers, ultimately reducing the cost of the product. EPDM has such comprehensive properties as good processability, low cost, light weight, and excellent insulation properties, which makes it widely used in the electrical field. In order to prevent the current-carrying conductive element from coming in contact with other elements and provide the conductor with suitable mechanical support, the insulating material may be thinly coated on the conductor.

Thermal overload in conductors (caused by defective joints) is a potential source of sparks that can cause entire electrical installations to be in danger. Because the polymer in the cable jacket is a highly flammable material. Therefore, in the field of electrical applications, special preventive measures need to be taken for the possibility of ignition of polymer materials.

Microbend Mass Flow Meter

Sealand is a trustworthy manufacturer of Microbend Mass Flow Meter, Microbend Mass Flowmeter, Microbend Coriolis Mass Flow Meter, Microbend Coriolis Mass Flowmeter.

Site Selection for Mass Flow Meter Installation
a) Sensor stays away from mechanical vibration source, for example, pump. Use flexible pipe to connect meter with pipeline if inevitable. The housing of meter must be standalone, out of touch with any other device. There must be 3 times the size of sensor between 2 sensors if there are many flow meters on the same pipeline, to avoid resonance.
b) Do not install sensor on pipeline that easily expands with hot and contracts with cold, especially near expansion joint, which leads to a worse stability.
c) Sensor stays away from industrial electromagnetic field, such as large generator and transformer, better 5m at least. Such device influences the performance of drive coil and pickoffs. Make sure magnetic field intensity less than 400A/m.
d) Sensor shall be installed on lower pipeline, to be easily full of fluid.
e) Make sure Ex-mark meet application requirements if in hazardous area.
f) Build a sunshade if the meter is under direct solar radiation. g) Keep the meter from corrosive liquid.